Replacing a Two-Position SCSI Disk Drive Bay
To replace a two-position SCSI disk drive bay, use the following procedure:
1. If you have not already done so, shut down the system as described in “Stopping
the System Unit” on page 306.
2. If you have not already done so, remove the front and right side covers as
described in “Removing the Covers” on page 301.
3. Remove the cover from the two-position disk drive bay.
4. Slide the disk drive bay cage into the system as shown in the following diagram.