Compex SCSI TO S-ATA RAID Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Networking Compex SCSI TO S-ATA RAID. Compex SCSI TO S-ATA RAID Product specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 258
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - Operation Manual

SCSI to SATA RAID Subsystems Operation Manual Version 1.2 (03, 2006)Firmware Revision: 3.47x

Strona 2 - Contact Information

x About This Manual This manual provides all of the necessary information that a system administrator needs to configure and maintain EonStor SCSI to

Strona 3 - Copyright 2006

Infortrend 4-30 Figure 4 - 48: Media Scan Screen There are two options with performing the Media Scan: 1. Media Scan Priority: determines how mu

Strona 4 - Table of Contents

Terminal Operation 4-31 4.11 Viewing and Editing Host LUNs 4.11.1 Viewing or Deleting LUN Mappings Choose the host channel and host ID combination

Strona 5

Infortrend 4-32 Press [ENTER] on a selected drive to view a sub-menu featuring functions related to the individual hard drive. Figure 4 - 52: View

Strona 6

Terminal Operation 4-33 Figure 4 - 53: Delete Global/Local Spare Drive Page NOTE: The spare drive you deleted or any drive you replaced from a logi

Strona 7 - Chapter 7 Data Integrity

Infortrend 4-34 4.12.3 Identifying Drives Figure 4 - 56: Identify Drive Page Whenever there is a failed drive in a logical drive, make it a point t

Strona 8 - Chapter 8 Array Expansion

Terminal Operation 4-35 4.12.3.2 Flash All Drives The Read/Write LEDs of all connected drives will light for a configurable period of time. If the LE

Strona 9 - Appendix C. Event Message

Infortrend 4-36 The drive-identifying function can be selected from “Main Menu”/”View and Edit Drives”/”Identify Drives.” 4.12.4 Media Error Reassi

Strona 10 - About This Manual

Terminal Operation 4-37 Figure 4 - 61: View and Edit Channels Page Choose View and Edit Channels in the Main Menu to display channel status. Fig

Strona 11 - Related Documentations

Infortrend 4-38 4.13.2 Adding an ID Figure 4 - 64: Add ID Screen Press [ENTER] on one of the existing IDs. Choose Add Channel ID, and then choose

Strona 12 - WARNING!

Terminal Operation 4-39 • At least one controller’s ID has to be present on each channel bus. 4.13.4 Data Rate (Channel Bus) Figure 4 - 66: Data R

Strona 13

xi Chapter 7 Details various methods, either manual or automatic, for maintaining array data integrity. Chapter 8 Shows how to expand a configured

Strona 14 - LCD Screen Messages

Infortrend 4-40 4.13.5 View Chip Information Figure 7 - 67: View Chip Information This is a view only option showing basic information about the S

Strona 15 - 1.3 Logical Drive Status

Terminal Operation 4-414.14.1 Mute Beeper Figure 4 - 69: Mute Beeper Screen When the subsystem’s beeper (onboard alarm) has been activated, choose

Strona 16

Infortrend 4-42 character space. The maximum numbers of characters for the controller password is 32. If the controller name occupies 32 characters, t

Strona 17 - 1.5 Drive Status

Terminal Operation 4-434.14.6 Reset Controller Figure 4 - 72: Reset Controller Screen To reset the controller without powering off the system, mov

Strona 18 - CH0=Host =

Infortrend 4-44 4.14.8 Adjust LCD Contrast Figure 4 - 74: Adjust LCD Contrast Page The controller LCD contrast is set at the factory to a level tha

Strona 19

Terminal Operation 4-454.15.2 LCD Title Display - Controller Name Figure 4 - 76: Controller Parameters Screen Choose View and Edit Configuration Pa

Strona 20

Infortrend 4-46 A prompt will inform you that NVRAM information was successfully saved. 4.15.4 Restore NVRAM from Disks Use this function to restore

Strona 21

Terminal Operation 4-474.15.6 Controller Unique Identifier Figure 4 - 80: View and Edit Configuration Parameters Enter any hex number between “0” a

Strona 22 - LCD Keypad Operation

Infortrend 4-48 Time Zone Figure 4 - 81: Set Controller Date and Time Page The controller uses GMT (Greenwich Mean Time), a 24-hour clock. To cha

Strona 23

Terminal Operation 4-494.16 View Drive Information Figure 4 - 83: View Drive Information Page From the “View and Edit Drives” menu, select the dri

Strona 24

xii Conventions Naming From this point on and throughout the rest of this manual, the EonStor series is referred to as simply the “subsystem” or the

Strona 25 - 2.2.5 Periodic Cache Flush

Infortrend 4-50 When finished with the configuration, select Execute Drive Testing and press [ENTER] to proceed. The Read/Write test progress will

Strona 26 - 2.3 View Connected Drives:

Terminal Operation 4-51 4...

Strona 27

Infortrend 4-52 4.12.3 Identifying Drives ...34

Strona 28 - 2.4.7 Write Policy

Host-side and Drive-side Parameters 8-1 Host-side and Drive-side Parameters This chapter discusses the advanced options for configur

Strona 29 - 2.4.9 Stripe Size

Infortrend 8-2 Figure 5 - 1: SCSI ID/LUNs Figure 8-1 illustrates this idea. If you file a document into a cabinet, you must put the documen

Strona 30

Host-Side and Drive-Side Parameters 8-3From the Main Menu, select “View and Edit Configuration Parameters,” “Host-side Parameters,” then press [EN

Strona 31 - 2.5.2 Write Policy

Infortrend 8-4 Figure 5 - 4: Maximum Queued I/O Count Choose “Host-side Parameters,” then press [ENTER]. Choose “Maximum Queued I/O Count,” then pr

Strona 32

Host-Side and Drive-Side Parameters 8-55.1.5 LUN Applicability If no logical drive has been created and mapped to a host LUN, and the RAID control

Strona 33 - Drive to Host LUN

Infortrend 8-6 monitoring and administration. In addition to the regular RS-232C or Ethernet connection, in-band SCSI can serve as an alternative mean

Strona 34 - Settings

Host-Side and Drive-Side Parameters 8-7 Figure 5 - 7: Peripheral Device Type Parameters Operating System Peripheral Device Type Peripheral Devi

Strona 35 - 2.8.3 Rebuild Settings

xiii Software and Firmware Updates Please contact your system vendor or visit Infortrend’s FTP site (ftp.infortrend.com.tw) for the latest software

Strona 36 - Drive Members

Infortrend 8-8 5.1.9 Cylinder/Head/Sector Mapping Drive capacity is decided by the number of blocks. For some operating systems (Sun Solaris, for exa

Strona 37

Host-Side and Drive-Side Parameters 8-9Configuring Sector Ranges/Head Ranges/Cylinder Ranges: Selecting Sector Ranges Figure 5 - 8: Selecting Se

Strona 38

Infortrend 8-10 Figure 5 - 10: Selecting Cylinder Ranges 5.2 Drive-side Parameters: Figure 5 - 11: Drive Side Parameters Screen Choose “D

Strona 39

Host-Side and Drive-Side Parameters 8-115.2.1 Disk Access Delay Time This feature sets the delay time before the subsystem tries to access the har

Strona 40

Infortrend 8-12 receive an I/O timeout when devices of higher priority keep utilizing the bus. The default setting for “Drive I/O Timeout” is 7 secon

Strona 41 - 2.9.7 Write Policy

Host-Side and Drive-Side Parameters 8-13 Figure 5 - 14: Selecting Maximum Tag Count This sub-menu facilitates the support for both Tagged Command

Strona 42

Infortrend 8-14 5.2.4 Drive Spindown Idle Delay Period Figure 5 - 15: Selecting Drive Spindown Idle Delay Period This is power saving feature

Strona 43 - 2.12.3 Deleting a Channel ID

Host-Side and Drive-Side Parameters 8-15 Figure 5 - 16: Enabling/Disabling Delayed Write This option allows to utilize the cache buffer embedde

Strona 44

Infortrend 8-16 5.1 HOST-SIDE PARAMETERS... 1 Foreword: SCSI Channel,

Strona 45 - 2.12.4 Data Rate

Enclosure Management 9-1 Enclosure Management This chapter discusses the configuration options related to enclosure monitoring. Each

Strona 46 - 2.13 System Functions

LCD Screen Messages 1-1 LCD Screen Messages 1.1 The Initial Screen Figure 1 - 1: LCD Initial Screen Status/Data Transfer Indicator: Ready The

Strona 47 - 2.13.4 Shutdown Controller

Infortrend 9-2 Select “View and Edit Peripheral Devices” on the Main Menu and press [ENTER]. Choose “Set Peripheral Device Entry”, press [ENTER],

Strona 48 - 2.13.6 Saving NVRAM to Disks

Enclosure Management 9-3level I/O board or the daughter card. If any of the threshold values set for any sensor is exceeded, the trigger automati

Strona 49 - 2.14.1 Controller Name

Infortrend 9-4 6.1.1.2 Dynamic Caching Mode Switch Controller Auto-Shutdown - Event Triggered Operations Figure 6- 4: Change Controller Shutdown P

Strona 50

Enclosure Management 9-5 Figure 6 - 5: View Peripheral Device Status The controller operation status displays. The enclosure fan status is sho

Strona 51 - 2.15 Drive Utilities

Infortrend 9-6 Figure 6 - 6: Set Trigger Thresholds Scroll down and select an item to configure. Figure 6 - 7: Change Threshold for CPU Temperat

Strona 52 - 2.15.1 Drive Read/Write Test

Enclosure Management 9-7Figure 6 - 9: Warning Message for Out of Range Follow the same method to modify other threshold parameters. 6.2 UPS

Strona 53

Infortrend 9-8 Figure 6 - 10: Set SAF-TE and SES Check Time If there are remote components in your RAID enclosure being controlled via SAF-TE/S.E.S

Strona 54

Enclosure Management 9-9 1. Device type 2. Enclosure descriptor 3. Power supply 4. Cooling element 5. Temperature Sensors 6. Audible alarm 7. E

Strona 55 - Limitations on optimization

Infortrend 9-10 This page is intentionally left blank

Strona 56

Enclosure Management 9-11 6.1 ENCLOSURE MONITORING... 1 6.1

Strona 57 - Terminal Screen Messages

Infortrend 1-2 Press [ENT] to create a logical drive. The subsystem/controller will start initialization of one logical drive to include all connecte

Strona 58

Data Integrity 7-1 Data Integrity This chapter discusses various firmware mechanisms that help to secure the integrity of array data

Strona 59 - 3.3 Quick Installation

Infortrend 7-2 7.1 Failed Drive Detection 7.1.1 Periodic Drive Check Time The “Periodic Drive Check Time” is the time interval for the controll

Strona 60 - 3.4 Logical Drive Status

Data Integrity 7-37.1. 2 Periodic Auto-Detect Failure Drive Swap Check Time The “Drive-Swap Check Time” is the interval at which the controller c

Strona 61

Infortrend 7-4 IMPORTANT! • The "Periodic Drive Check Time” is enabled by choosing a time value. The RAID controller will poll all connected

Strona 62 - 3.6 Drive Status

Data Integrity 7-5 A member of another logical drive fails.  The subsystem has no spare left. Performance decreases for a considerable portio

Strona 63

Infortrend 7-6 The scheduler is accessed through the “View and Edit Logical Drives” menu by selecting a configured array to display the list of array-

Strona 64 - 3.7 Channel’s Status

Data Integrity 7-7Execute on Controller Initialization Figure 7 - 8: Set for Task Scheduler Function This option determines whether Media Scan

Strona 65

Infortrend 7-8 • If the action is intended to be executed for one time only, select “Execution Once.” • In the case of a periodic action, the act

Strona 66

Data Integrity 7-9Select Logical Drives Figure 7 - 13: Set for Logical Drive Press [ENTER] on “Select Logical Drives” to bring out a sub-menu.

Strona 67

Infortrend 7-10 7.3 Regenerating Logical Drive Parity Figure 7 - 15: Regenerate Logical Drive Parity Parity regeneration is a function manually

Strona 68

LCD Screen Messages 1-3 Logical Drive status: XxxxMB The capacity of this logical drive. SB=x Standby drives available to this logical drive. Except

Strona 69

Data Integrity 7-11 Figure 7 - 16: Set for Disk Array Parameters Select “View and Edit Configuration Parameters” on the Main Menu and press [ENT

Strona 70

Infortrend 7-12  Verification on LD Initialization Writes Performs Verify-after-Write when initializing a logical drive  Verification on LD Rebuil

Strona 71 - Terminal Operation

Data Integrity 7-13 7.1 FAILED DRIVE DETECTION ... 2 7.1.1 Pe

Strona 72 - 4.2 Caching Parameters

Array Expansion 8-1 Array Expansion The array expansion functions allow you to expand storage capacity without the cost of buying new

Strona 73 - Opt. for Random I/O

Infortrend 8-2 added, the capacity will be increased to 144GB in two separate partitions (one is 108GB and the other 36GB). 2. Size of the New D

Strona 74

Array Expansion 8-3RAID levels supported: RAID 0, 1, 3, 5 and 6 Expansion can be performed on logical drives or logical volumes under the followin

Strona 75

Infortrend 8-4 RAID levels supported: RAID 0, 1, 3, 5, and 6. The new partition must be made available through a host ID/LUN. Add Drive Procedure

Strona 76

Array Expansion 8-5Available drives will be listed. Select one or more drive(s) to add to the target logical drive by pressing [ENTER]. The selec

Strona 77 - 4.4.1 Choosing a RAID Level

Infortrend 8-6 Figure 8 – 8: Completion of Add Drive Function The added capacity will be automatically included, meaning that you do not have to &

Strona 78 - 4.4.2 Choosing Member Drives

Array Expansion 8-7When all the member drives have been replaced, execute the “Expand Logical Drives” function to make use of the added capacity.

Strona 79 - 4.4.3.5 Initialization Mode

Infortrend 1-4 1.4 Logical Volume Status Figure 1 - 4: Logical Volume Status Screen Logical Volume: The Logical Volume number. DRV=x: Th

Strona 80 - 4.4.3.6 Stripe Size

Infortrend 8-8 The array members will be listed. Select the member drive (the source drive) you want to replace with a larger one. Figure 8 – 11:

Strona 81 - 4.5 RAID Migration

Array Expansion 8-9 Figure 8 – 14: View Copy and Replace Progress Completion of the Copy and Replace process will be indicated by a notification

Strona 82 - 4.5.2 Migration Methods

Infortrend 8-10 Figure 8 – 16: Expand Logical Drive Choose Yes to confirm and proceed. Figure 8 – 17: Choose Expand Logical Drive Upon co

Strona 83

Array Expansion 8-118.6 Expand Logical Volume To expand a logical volume, expand its logical drive member(s) and then perform “expand logical vo

Strona 84 - Figure 4 - 19: Confirm Box

Infortrend 8-12 Example The following example demonstrates the expansion of a 16988MB RAID 5 logical drive. The HyperTerminal emulation software tha

Strona 85 - Figure 4 - 23: Confirm Box

Array Expansion 8-13 Figure 8 – 23: View Disk Information Follow the steps described in the previous section to "add" or "copy &a

Strona 86

Infortrend 8-14 Figure 8 – 25: Choose Logical Drive From the menu, select "Partition Logical Drive." You will see that the 25GB logical

Strona 87

Array Expansion 8-15 Figure 8 – 27: View Disk information on Windows Select an existing volume (Disk1) and then right-click on the disk column.

Strona 88 - Figure 4 - 27: Confirm Box

Infortrend 8-16 The Extend Volume Wizard will guide you through the rest of the process. Figure 8 – 29: Configure Disk Volume The screen will di

Strona 89

Array Expansion 8-17 Figure 8 – 31: View Disk Information

Strona 90

LCD Screen Messages 1-5Drive Status: LG=x IN Initializing LG=x LN On-line (already a member of a logical configuration) LG=x RB Rebuilding LG=x SB Lo

Strona 91

Infortrend 8-18 This page is intentionally left blank

Strona 92

Array Expansion 8-19 8.1 Overview ...

Strona 93

S.M.A.R.T. Configuration 9-1 S.M.A.R.T. Configuration 9.1 Overview S.M.A.R.T. With the maturity of technologies like S.M.A.R.T., drive fail

Strona 94

Infortrend 9-2 9.1.2 Replace after Clone Data on the source drive, the drive with predicted errors (or any selected member drive), will be cloned t

Strona 95

S.M.A.R.T. Configuration 9-3The cloning process will be indicated by a status bar. You may quit the status bar by pressing [ESC] to return to the

Strona 96

Infortrend 9-4 Figure 9 – 6: Select Perpetual Clone Drive The controller will automatically start the cloning process using the existing “stand-b

Strona 97

S.M.A.R.T. Configuration 9-5 Figure 9 – 9: Identify The Source Drive The cloning progress will be completed by a notification message as displaye

Strona 98

Infortrend 9-6 for disk drives. When S.M.A.R.T. is enabled, the drive monitors predetermined disk drive attributes that are susceptible to degradati

Strona 99 - 4.10.9 Media Scan

S.M.A.R.T. Configuration 9-7Detect and Perpetual Clone When the S.M.A.R.T. function is enabled, the controller will send a command to enable all

Strona 100 - 4.10.10 Write Policy

Infortrend 9-8 Figure 9 – 12: Select Drive Check Time Step 2. In \View and Edit Configuration Parameters\Drive-side Parameters\Drive Predictable

Strona 101

Infortrend 1-6 Channel Mode: Host Host channel mode Drive Drive channel mode Default SCSI Bus Sync Clock: 160M The default setting of

Strona 102 - Function Availability

S.M.A.R.T. Configuration 9-9Examining Whether Your Drives Support S.M.A.R.T. To see if your drive supports S.M.A.R.T., follow the steps below:

Strona 103 - 4.12.2 Disk Reserved Space

Infortrend 9-10 message appears, it means your drive supports S.M.A.R.T. features. Step 6. If the error message does not appear, you may simply

Strona 104 - 4.12.3 Identifying Drives

S.M.A.R.T. Configuration 9-114a. In \View and Edit Configuration Parameters\Drive-side Parameters\Drive Predictable Failure Mode <SMART>, c

Strona 105 - 4.12.3.2 Flash All Drives

Infortrend 9-12 5c. When a drive (a logical drive member) detects the predictable drive failure, the controller will “clone” the drive with a spare

Strona 106

Implementations for AV Applications 13-1 Implementations for AV Applications This chapter introduces some new firmware functions for

Strona 107 - IMPORTANT!

Infortrend 13-2 Figure 10 - 1: Selecting Maximum Drive Response Timeout Value To prepare the array for read-intensive applications, the followin

Strona 108 - 4.13.3 Deleting an ID

Implementations for AV Applications 13-3 Figure 10 - 2: Selecting An AV Optimization Mode The applicable number of streaming for fewer/multiple st

Strona 109

Infortrend 13-4 10.1 MAXIMUM DRIVE RESPONSE TIME ...1 10.2 AV OPTIM

Strona 110 - 4.14 System Functions

Firmware Functionality Specifications A-1 Firmware Functionality Specifications A.1 Basic RAID Management: Specification Feature RAID levels 0

Strona 111 - 4.14.2 Change Password

Infortrend A-2 Maximum number of partitions for each logical drive 16 as default, up to 64 with a 1GB memory size Maximum number of logical volumes 8

Strona 112 - 4.14.3 Changing the Password

ii Contact Information Asia Pacific (International Headquarters) Infortrend Technology, Inc. 8F, No. 102 Chung-Shan Rd., Sec. 3 Chung-Ho City, Tai

Strona 113 - 4.14.7 Shutdown Controller

LCD Screen Messages 1-7 1.8 View and Edit Event Logs Press ENT for two seconds to enter the Main Menu. Press the up or down arrow keys to select

Strona 114 - 4.15 Controller Parameters

Firmware Functionality Specifications A-3NOTE: Regenerate Parity and Rebuild cannot take place on a logical drive at the same time. Create, Expand,

Strona 115 - 4.15.3 Saving NVRAM to Disks

Infortrend A-4 Bad Block Handling in degraded mode A method for handling low quality drives. The operation is performed on both the logical drive in

Strona 116

Firmware Functionality Specifications A-5Host LUN geometry: user configurable default geometry (Solaris OSes) 1. Capacity <64GB: Head=63, Sector=3

Strona 117

Infortrend A-6 Supported memory type SDRAM or DDR memory for enhanced performance Fast Page Memory with Parity for enhanced data security Read-ahead

Strona 118 - Date and Time

Firmware Functionality Specifications A-7A.4 RAID Expansion: On-line RAID expansion Supported. Capacity brought by array expansion is immediately rea

Strona 119 - 4.17 Drive Utilities

Infortrend A-8 Synchronized cache Supported. Through one or multiple, dedicated synchronizing channels on a common backplane or external cabling. S

Strona 120

Firmware Functionality Specifications A-9Load sharing Supported. Workload can be flexibly divided between different controllers by assigning logical

Strona 121

Infortrend A-10 drives. Verification on LD initialization writes Supported. Performs read-after-write during logical drive initialization to ensure

Strona 122

Firmware Functionality Specifications A-11A.9 Environment Management: SAF-TE/S.E.S. support Supported. The SAF-TE/S.E.S. modules can be connected to

Strona 123 - Parameters

Infortrend A-12 user configurable. On-board controller temperature sensors Supported. Monitors the CPU and board temperature status. Event trigger

Strona 124 - Figure 5 - 1: SCSI ID/LUNs

Infortrend 1-8 LCD Screen Messages... 1-1 1.1 The Initial Screen ...

Strona 125 - Connection

Firmware Functionality Specifications A-13 Firmware Functionality...1 Specifications...

Strona 126 - 5.1.4 LUNs per Host ID

System Functions: Upgrading Firmware B-1 System Functions: Upgrading Firmware B.1 Upgrading Firmware The RAID controller’s firmware resides

Strona 127 - 5.1.7 In-band (SCSI channel)

Infortrend B-2B.1.2 Note for Redundant Controller Firmware Upgrade: A controller used to replace a failed unit in a dual-controller system is often

Strona 128 - Operating Systems

System Functions: Upgrading Firmware B-3B.2.2 Upgrade Both Boot Record and Firmware Binaries Figure B - 1: Upgrading Boot Record and Firmware Binar

Strona 129

Infortrend B-4B.2.3 Upgrade the Firmware Binary Only Figure B - 2: Upgrading Firmware Binaries Using RAIDWatch Program 1. Connect to the RAID sy

Strona 130

System Functions: Upgrading Firmware B-5B.3 Upgrading Firmware Using RS-232C Terminal Emulation The firmware can be downloaded to the RAID controller/

Strona 131

Infortrend B-66. Send the Boot Record Binary to the controller. In HyperTerminal, go to the "Transfer" menu and choose "Send file.&qu

Strona 132 - 5.2 Drive-side Parameters:

System Functions: Upgrading Firmware B-7 Figure B - 5: Sending Files 6. When the Firmware completes downloading, the controller will automatically

Strona 133 - 5.2.2 Drive I/O Timeout

Infortrend B-8 This page is intentionally left blank

Strona 134

System Functions: Upgrading Firmware B-9 System Functions: Upgrading Firmware...

Strona 135

LCD Keypad Operation 2-1 LCD Keypad Operation A navigation roadmap for the configuration menu options of LCD keypad is separately available a

Strona 136 - 5.2.5 Drive Delayed Write

Event Messages C-1 Event Messages The controller events can be categorized as follows according to the severity levels: Critical Errors that n

Strona 137

Infortrend C-2 Event Index C.1 Logical Drive Events C.1.1 Critical: LG:0 Logical Drive ALERT: CHL:0 ID:132 Drive Missing LG:0 Logical Drive ALERT

Strona 138

Event Messages C-3LG:0 Logical Drive NOTICE: On-Line Expansion of Logical Drive Completed LG:0 Logical Drive NOTICE: Starting Off-Line Expansion LG:0

Strona 139 - Enclosure Management

Infortrend C-4 C.2 Channel and Individual Drive Events C.2.1 Critical: CHL:0 ID:132 ALERT:Media Error Unrecoverable-0xD8001C7C CHL:0 FATAL ERROR(0)

Strona 140 - The Trigger

Event Messages C-5CHL:0 Host Channel ALERT: Channel Failure SMART-Slot:-1 Predictable Failure Detected-Clone Failed SMART-Slot:-1 Predictable Failure

Strona 141

Infortrend C-6 C.3 General Target Events C.3.1 Critical: SAF-TE Device(0)ALERT: Power Supply Failure Detected(Idx:132) Peripheral Set 0 Device ALERT

Strona 142 - Operations

Event Messages C-7Peripheral Set 2 Device NOTICE: PSU0 +12V Back On-Line(5.0V) SES(C0 I0)Power Supply 2:Power Supply Back On-Line UPS Connection Detec

Strona 143

Infortrend C-8 C.4 Controller Events C.4.1 Critical: ALERT: +3.3V Low Voltage Detected(205.9V) ALERT: Controller FAN 0 Low Speed Detected(0 RPM) Co

Strona 144

Event Messages C-9Event Description C.5 Logical Drive Events C.5.1 Critical: Message LG:0 Logical Drive ALERT: CHL:0 ID:132 Drive Missing What Hap

Strona 145 - 6.2 UPS Support

Infortrend C-10 Message LG:0 Logical Drive ALERT: Rebuild Failed What Happens? Logical drive rebuild failed. It could result from the one of the foll

Strona 146

Infortrend 2-2 2. You can select the stripe size of each array (logical drive) during the initial configuration. However, changing stripe size is on

Strona 147 - C Device Information

Event Messages C-11Message LG:0 Logical Drive ALERT: Initialization Failed What Happens? Logical drive initialization failed. It could result from on

Strona 148 - This page is intentionally

Infortrend C-12 Message LG:0 Logical Drive ALERT: CHL:0 ID:132 Clone Failed What Happens? Drive cloning failed. It could result from one of the follo

Strona 149

Event Messages C-13Message LG:0 Logical Drive ALERT: Bad Data Block Marked 000000084 What Happens? Media errors caused data inconsistency; e.g., concu

Strona 150 - Data Integrity

Infortrend C-14 Message LG:0 Logical Drive NOTICE: Starting Rebuild What Happens? The rebuild process has begun. What to Do? This is the message displ

Strona 151

Event Messages C-15Message LG:0 Logical Drive NOTICE: Starting Off-Line Initialization What Happens? Creation process is completed, initialization pr

Strona 152

Infortrend C-16 Message LG:0 Logical Drive NOTICE: Continue Add Drive Operation What Happens? The target logical drive has been restored to its previ

Strona 153

Event Messages C-17Message LG:0 Logical Drive NOTICE: CHL:0 ID:132 Continue Clone Operation What Happens? The target logical drive has been restored t

Strona 154 - 7.2.1 Task Scheduler

Infortrend C-18 C.6 Channel and Individual Drive Events C.6.1 Critical: Message CHL:0 ID:132 Target ALERT: Media Error Unrecoverable-0xD8001C7C Wha

Strona 155 - 7.2.2 Task Scheduler Options

Event Messages C-19Message CHL:_ Drive Channel ALERT: Gross Phase/Signal Error Detected What Happens? Phase/signal abnormality detected on the specifi

Strona 156 - Execution Period

Infortrend C-20 Message CHL:_ ID:_ Host Channel ALERT: Parity/CRC Error Detected What Happens? Parity or CRC errors detected through host ID, CHL_ ID_

Strona 157 - Media Scan Priority

LCD Keypad Operation 2-32.2.2 Optimization Mode and Stripe Size Each controller optimization mode has preset values for the stripe size of arrays cre

Strona 158 - Select Logical Drives

Event Messages C-21Message CHL:_ Drive Channel ALERT: Unit Attention Received (10B) What Happens? Drive-side target unit attention receive on a drive

Strona 159

Infortrend C-22 Message CHL:_ RCC Channel ALERT: Negotiation Error Detected What Happens? Negotiation errors occurred on the RCC channel CHL:_. What

Strona 160

Event Messages C-23Message CHL:_ Host Channel ALERT: Channel Failure What Happens? Host channel CHL:_ link failure or disconnection occurred. What t

Strona 161

Infortrend C-24 Message CHL:_ ALERT: Redundant Path for CHL:_ ID:_ Expected but Not Found What Happens? One of the dual loop members may have failed

Strona 162

Event Messages C-25 Message CHL:_ ID:_ Drive NOTICE: Drive Recovered Error Reported What Happens? Hard drive unrecoverable media error reported. A ba

Strona 163 - Array Expansion

Infortrend C-26 C.7 General Target Events C.7.1 Critical: Message SAF-TE Device(0) ALERT: Power Supply Failure Detected(Idx:132) What Happens? Power

Strona 164 - 3. Applicable Arrays:

Event Messages C-27Message Peripheral Set 0 Device ALERT: Cooling Fan 2 Note Present What Happens? No cooling fan module is installed in the expected

Strona 165 - 8.3 Mode 1 Expansion:

Infortrend C-28 Message Peripheral Set 0 Device ALERT: Temperature Sensor 0 Not Present What Happens? Temperature sensor failed or serial bus configur

Strona 166 - Add Drive Procedure

Event Messages C-29Message Warning: UPS AC Power-Loss Detected What Happens? UPS AC power loss reported through the COM2 serial port connection.

Strona 167 - Figure 8 – 5: Select Drives

Infortrend C-30 Message Peripheral Set 0 Device NOTICE: FAN 1 Back On-Line(_RPM) What Happens? An individual cooling fan once missing or failed is res

Strona 168 - Larger Capacity

Infortrend 2-4 2.2.4 Write-back/Write-through Cache Enable/Disable As one of the submenus in "Caching Parameters," this option controls the

Strona 169 - Copy and Replace Procedure

Event Messages C-31 Message Power Supply 0 Back-Online What Happens? Power supply module 0 is back online What to Do? Press ESC to clear this message

Strona 170

Infortrend C-32 Message SES(C0 I0)UPS 2: UPS Power Back On-Line What Happens? UPS 2 connected through SES interface reports power back online. What to

Strona 171 - Expand Logical Drive

Event Messages C-33C.8 Controller Events C.8.1 Critical: Message ALERT: +3.3V Low Voltage Detected(_._V) What Happens? The detected +3.3V voltage so

Strona 172

Infortrend C-34 Message Controller PCI Bus Parity Errors Detected What Happens? Serious system faults have occurred. What to Do? Stop host I/Os i

Strona 173 - Extension in Windows 2000

Event Messages C-35 Message Controller BBU Thermal Shutdown/Enter Sleep-Mode! What Happens? The following conditions will cause the charger circuits t

Strona 174 - Example

Infortrend C-36 Message +12V Lower Voltage Back within Acceptable Limits (_._V) What Happens? +12V voltage dropped back within preset thresholds. What

Strona 175

Event Messages C-37Message Force Controller Write-Through on Trigger Cause What Happens? Preset conditions, e.g., elevated temperature or component fa

Strona 176

Infortrend C-38 This page is intentionally left blank

Strona 177

Event Messages C-39 Event Messages...

Strona 178

LCD Keypad Operation 2-5 IMPORTANT! • Every time you change the caching parameters, you must reset the controller for the changes to take effect.

Strona 179

Infortrend 2-6 IMPORTANT! • Drives of the same brand/model/capacity might not feature the same block number. • The basic read/write unit of a har

Strona 180

LCD Keypad Operation 2-7available drives. Press ENT again to select/deselect the drives. An asterisk (*) mark will appear on the selected drive(s). To

Strona 181

Infortrend 2-8 coordinated with the subsystem’s caching mode setting. Other choices are “Write-back” and “Write-through.” 2.4.8 Initialization Mode

Strona 182 - S.M.A.R.T. Configuration

iii Copyright 2006 This Edition First Published 2006 All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,

Strona 183 - 9.1.2 Replace after Clone

LCD Keypad Operation 2-9for two seconds to start initializing the logical drive. The Online Mode: If the online initialization method is applied,

Strona 184 - 9.1.3 Perpetual Clone:

Infortrend 2-10 Proceed to select one or more logical drives. Press ENT to proceed. “LD” is short for Logical Drive. Use the up or down arrow keys

Strona 185

LCD Keypad Operation 2-11 2.6 Partitioning a Logical Drive/Logical Volume Partitioning a

Strona 186 - 9.1.4 S.M.A.R.T

Infortrend 2-12 IMPORTANT! If operated with a Unix-based system, reset the subsystem for the configuration to take effect if any changes have been ma

Strona 187 - Detect Only:

LCD Keypad Operation 2-13you can map the whole capacity to a host LUN. Press ENT for two seconds when prompted by “Map Host LUN” to proceed. Mapp

Strona 188 - NOTE:

Infortrend 2-14 spare drive or failed drive, then press ENT to select it. Press the up or down arrow keys to select “Add Local Spare Drive,” then pre

Strona 189

LCD Keypad Operation 2-15press ENT. “Low” refers to the temporary default setting. Press ENT again and the abbreviation mark “..” will change to a

Strona 190

Infortrend 2-16 Deleting a logical drive erases all data stored in it. Press ENT for two seconds to enter the Main Menu. Press the up or down arro

Strona 191 - Using S.M.A.R.T. Functions

LCD Keypad Operation 2-17 Figure 2 - 1 Drive Space Allocated to the Previous Partition WARNING! Whenever there is a partition change, data will be

Strona 192

Infortrend 2-18 2.9.4 Rebuilding a Logical Drive (Manual Rebuild) If you want the controller to auto-detect a replacement drive, make sure you have th

Strona 193

iv Table of Contents Chapter 1 LCD Screen Messages 1.1 The Initial Screen...

Strona 194 - Applications

LCD Keypad Operation 2-192.9.5 Regenerating Logical Drive Parity If no verifying method is applied to data writes, this function can be manually perfo

Strona 195 - 10.2 AV Optimization Mode

Infortrend 2-20 Press ENT again to display the first configuration option, “Priority.” Press ENT on it and use arrow keys to select an option. Pre

Strona 196

LCD Keypad Operation 2-212.10 Viewing and Editing Host LUNs Press ENT for two seconds to enter the Main Menu. Press the up or down arrow keys to s

Strona 197

Infortrend 2-22 2.12 Viewing and Editing Channels 2.12.1 Viewing IDs Press ENT for two seconds to enter the Main Menu. Press the up or down arrow

Strona 198 - Specifications

LCD Keypad Operation 2-23 A list of host channel and host ID combinations will appear. Use the up or down arrow keys to select an ID you wish to remo

Strona 199

Infortrend 2-24 2.12.4 Data Rate This option is available in the configuration menu of SCSI host channel and the drive channel configuration menus of

Strona 200 - A.2 Advanced Features:

LCD Keypad Operation 2-25To AUTO?”, where “X” stands for the channel number. Use your arrow keys to display a data rate value which ranges from 33

Strona 201

Infortrend 2-26 2.13.2.1 Change Password To set or change the controller password, press the up or down arrow keys to select “Change Password,” then p

Strona 202 - A.3 Caching Operation:

LCD Keypad Operation 2-272.13.5 Controller Maintenance For Controller Maintenance functions, please refer to Appendix C. 2.13.6 Saving NVRAM to Disks

Strona 203

Infortrend 2-28 2.13.8 Adjust LCD Contrast The controller LCD contrast is set at the factory to a level that should be generally acceptable. The contr

Strona 204 - A.6 Redundant Controller:

v 2.10 Viewing and Editing Host LUNs ... 2-21 2.11 Viewing and Editing Drives...

Strona 205

LCD Keypad Operation 2-292.14.3 Password Validation Timeout Choose “View and Edit Configuration Parameters,” “Controller Parameters,” then press ENT.

Strona 206 - A.7 Data Safety:

Infortrend 2-30 The controller uses GMT (Greenwich Mean Time), a 24-hours clock. To change the clock to your local time zone, enter the hours later

Strona 207 - A.8 System Security:

LCD Keypad Operation 2-312.15.1 Drive Read/Write Test From the “View and Edit Drives” menu, select a new or used drive that the utility is to be perfo

Strona 208 - A.9 Environment Management:

Infortrend 2-32 This page is intentionally left blank

Strona 209 - A.11 High Availability:

LCD Keypad Operation 2-33 2.1 Power On the RAID Enclosure 2-1 2.2 Caching Parameters 2-1 2.2.1 Optimization Modes 2-1 2.2.2 Optimization Mode a

Strona 210

Infortrend 2-34 2.13.8 Adjust LCD Contrast 2-28 2.14 Controller Parameters 2-28 2.14.1 Controller Name 2-28 2.14.2 LCD Title Display Controller N

Strona 211 - Upgrading Firmware

LCD Keypad Operation 2-35Off-Line Mode Initialization, 9 On-Line Mode Initialization, 9 Optimization Mode, 1 Optimization Mode LCD, 1 parameters cache

Strona 212 - Manager

Terminal Screen Messages 3-1 Terminal Screen Messages 3.1 The Initial Screen Figure 3 - 1: The RC-232C Initial Screen Chapter 3

Strona 213

Infortrend 3-2 Cursor Bar: Move the cursor bar to a desired item, then press [ENTER] to select Subsystem Name: Identifies the type of controller/subs

Strona 214 - RAIDWatch Program

Terminal Screen Messages 3-33.2 Main Menu Figure 3 - 2: The RC-232C Main Menu Use the arrow keys to move the cursor bar through the menu items, t

Strona 215 - Terminal Emulation

vi 4.4.3.2 Assign Spare Drives...4-9 4.4.3.3 Disk Reserved Space...

Strona 216 - Terminal Screen

Infortrend 3-4 Type Q or use the ↑ ↓ keys to select "Quick installation", then press [ENTER]. Choose Yes to create a logical drive. All po

Strona 217 - Figure B - 5: Sending Files

Terminal Screen Messages 3-5 INVALID The logical drive was created but has not been fully initialized when another version of firmware is being loade

Strona 218

Infortrend 3-6 3.5 Logical Volume Status Figure 3 - 5: Logical Volume Status Screen NOTE: • A logical volume in a single-controller subsystem i

Strona 219

Terminal Screen Messages 3-7 Slot Slot number of the disk drive Size (MB) Drive capacity Speed XXMB Maximum transfer rate of the drive channel inte

Strona 220 - Event Messages

Infortrend 3-8 3.7 Channel’s Status Figure 3 - 7: Channel Status Screen Chl Channel number Mode Channel mode Host Host Channel mode Drive Driv

Strona 221 - C.1 Logical Drive Events

Terminal Screen Messages 3-9 Diff The channel is a Differential channel. The terminator can only be installed/removed physically. N/A Non-SCSI bus

Strona 222

Infortrend 3-10 Figure 3 - 9: Controller Voltage and Temperature Status Screen The current status of voltage and temperature detected by the control

Strona 223 - C.2.2 Warning:

Terminal Screen Messages 3-11To clear the saved event logs, scroll the cursor down to select an event and press [ENTER] to delete the event and the e

Strona 224 - C.2.3 Notification:

Infortrend 3-12 This page is intentionally left blank

Strona 225 - C.3 General Target Events

Terminal Screen Messages 3-13 Terminal Screen Messages...3-1 3.1 The Initial Screen...

Strona 226

vii Chapter 5 Host Side and Drive Side Parameter 5.1 HOST-SIDE PARAMETERS ...

Strona 227 - C.4 Controller Events

Infortrend 3-2 V VT-100 Mode ...3-2 W Write Policy ...

Strona 228 - C.5 Logical Drive Events

Terminal Operation 4-1Chapter 4 Terminal Operation 4.1 Power on RAID Enclosure Hardware installation should be completed before powering on yo

Strona 229

Infortrend 4-2 4.2 Caching Parameters 4.2.1 Optimization Modes Mass storage applications can be roughly divided into two categories—database and vi

Strona 230

Terminal Operation 4-3The controller optimization modes have read-ahead buffer and other Read/Write characteristics tuned to obtain the best performan

Strona 231

Infortrend 4-4 Page Choose “Optimization for Random I/O” or “Optimization for Sequential I/O,” then press [ENTER]. The “Random” or “Sequential” dialo

Strona 232 - C.5.2 Notification:

Terminal Operation 4-54.2.5 Periodic Cache Flush Figure 4 - 4: Periodic Cache Flush Page If Write-back caching is preferred for better performance

Strona 233

Infortrend 4-6 4.3 Viewing the Connected Drives Prior to configuring disk drives into a logical drive, it is necessary to understand the status of t

Strona 234

Terminal Operation 4-74.4 Creating a Logical Drive Browse through the Main Menu and select View and Edit Logical Drive. Figure 4 - 6: View and E

Strona 235

Infortrend 4-8 4.4.2 Choosing Member Drives Choose your member drive(s) from the list of available physical drives. Tag the drives for inclusion by p

Strona 236

Terminal Operation 4-94.4.3.2 Assign Spare Drives Figure 4 - 9: Assign Spare Drives Page You can add a spare drive from the list of the unused drive

Strona 237

viii 7.2.3 Confirming the Creation of a Task Schedule ...7-9 7.3 REGENERATING LOGICAL DRIVE PARITY...

Strona 238

Infortrend 4-10 including the array into a logical volume, before the array’s initialization process is completed. 4.4.3.6 Stripe Size Figure 4 -

Strona 239

Terminal Operation 4-11 A controller event will then prompt to indicate that the logical drive initialization has begun. Press [ESC] to cancel the “N

Strona 240

Infortrend 4-12 Before proceeding with RAID migration, make sure you have sufficient free capacity or unused drives in your RAID array. RAID6 arrays

Strona 241

Terminal Operation 4-13 1. Fault condition: The usable capacity of the RAID6 array is smaller than the usable capacity of the original RAID5 array.

Strona 242

Infortrend 4-14 Figure 4 - 17: Migration Condition Met by Using Larger Drives 4.5.3 Migration: Exemplary Procedure To migrate a RAID5 array to RAI

Strona 243 - C.6.3 Notification:

Terminal Operation 4-15A selection box should prompt allowing you to choose a RAID level to migrate to. Press [ENTER] on RAID6. Figure 4 - 20: RA

Strona 244

Infortrend 4-16 Press [ESC] to clear the message. The initialization progress is shown below. Since the migration includes adding a new membe

Strona 245 - C.7 General Target Events

Terminal Operation 4-174.6 Creating a Logical Volume Figure 4 - 24: View and Edit Logical Volumes Screen A logical volume consists of one or severa

Strona 246

Infortrend 4-18 Figure 4 - 26: Selection Sub-menu Use the arrow keys to select a sub-menu and change the initialization mode, write policy, or the m

Strona 247

Terminal Operation 4-19 4.7 Partitioning a Logical Drive/Logical Volume The process of partitioning a logical drive is the same as that of partiti

Strona 248

ix Appendix B. System Functions: Upgrading Firmware B.1 Upgrading Firmware ...

Strona 249

Infortrend 4-20 Figure 4 - 31: Confirm Box When a partition of a logical drive/logical volume is deleted, the capacity of the deleted partition will

Strona 250

Terminal Operation 4-21Multiple IDs on host channels are necessary for redundant controller configuration. Details on creating multiple IDs and chang

Strona 251

Infortrend 4-22 5. When prompted to "Map Logical Volume?,” select Yes to continue. A prompt will display the mapping you wish to create. Cho

Strona 252 - C.8 Controller Events

Terminal Operation 4-23Choose View and Edit Drives on the Main Menu, then press [ENTER]. Move the cursor bar to a drive that is not assigned to a log

Strona 253

Infortrend 4-24 4.10 Viewing and Editing Logical Drives and Drive Members Choose View and Edit Logical Drives in the Main Menu to display the

Strona 254

Terminal Operation 4-25and task schedules 12. Write Policy Choose an appropriate write policy 4.10.1 Deleting a Logical Drive Choose the logical

Strona 255

Infortrend 4-26 Figure 4-42: Drive Space Allocated to the Previous Partition As illustrated above, the capacity of the deleted partition will be a

Strona 256

Terminal Operation 4-27If you want the controller to auto-detect a replacement drive, make sure you have the following items set to “enabled”: 1. Per

Strona 257

Infortrend 4-28 the available RAID levels according to the number of physical drives you selected will be shown on the screen. Use the Up and Down arr

Strona 258

Terminal Operation 4-29 Figure 4 - 46: Add Drive Screen 4.10.8 Regenerating Logical Drive Parity (Applies to RAID Levels 1, 3, 5, and 6) If no veri

Komentarze do niniejszej Instrukcji

Brak uwag