Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
4066 020E Scan interface basic assurance tests
detected memory pair A fault
Memory Pair A, Location: P1-M1.1 x2
4066 0211 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.13
4066 0212 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.3
4066 0213 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.14
4066 0214 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.4
4066 021D Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.3 x4
4066 0221 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.11
4066 0222 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.5
4066 0223 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.12
4066 0224 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.6
4066 022D Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.5 x4
4066 0231 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.9
4066 0232 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.7
4066 0233 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.10
4066 0234 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.8
4066 023D Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-M1.7 x4
4066 02FF Scan interface basic assurance tests
detected memory failure on riser card
1 that cannot be automatically
isolated.
Go to “MAP 1540: Minimum
Configuration” on page 52, and run
minimum configuration for further
isolation.
4066 0300 Scan interface basic assurance tests
detected processor card fault
Processor card Location: P1-C1
4066 0301 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-C1-M8
4066 0302 Scan interface basic assurance tests
detected memory DIMM fault
Memory DIMM Location: P1-C1-M1
Chapter 5. Error Code to FRU Index