Table 5. SPCN Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
1011 1B01 12V loading 1. Replace power supply V1
2. Use removed V1 to replace V2
3. Use removed V2 to replace V3 (if
present)
4. System board, Location: P1
1011 1B02 5V loading 1. Replace power supply V1
2. Use removed V1 to replace V2
3. Use removed V2 to replace V3 (if
present)
4. System board, Location: P1
1011 1B03 3.3V loading 1. Replace power supply V1
2. Use removed V1 to replace V2
3. Use removed V2 to replace V3 (if
present)
4. System board, Location: P1
1011 1B04 -12V loading 1. Replace power supply V1
2. Use removed V1 to replace V2
3. Use removed V2 to replace V3 (if
present)
4. System board, Location: P1
1011 1B05 1.8V loading 1. Replace power supply V1
2. Use removed V1 to replace V2
3. Use removed V2 to replace V3 (if
present)
4. System board, Location: P1
1011 1B06 2.5V loading 1. Replace power supply V1
2. Use removed V1 to replace V2
3. Use removed V2 to replace V3 (if
present)
4. System board, Location: P1
1011 1B07 2.5V loading 1. Replace power supply V1
2. Use removed V1 to replace V2
3. Use removed V2 to replace V3 (if
present)
4. System board, Location: P1
1011 2600 Power-good fault System board, Location: P1
1011 2601 Power-good fault System board, Location: P1
1011 2603 Power domain fault 1. Power supply, Location V1 or V2
or V3
2. System board, Location: P1
1011 2604 Power domain fault 1. Power supply, Location V1 or V2
or V3
2. System board, Location: P1
1011 2610 Missing or misplugged memory Inspect system memory for proper
installation of memory riser cards and
DIMMs.