Terminal Operation
4-23
Choose View and Edit Drives on the Main Menu, then press [ENTER].
Move the cursor bar to a drive that is not assigned to a logical drive or as
a spare drive (usually indicated as a "New Drive"), and then press
[ENTER].
Figure 4 - 36: Logical Drives List
Choose Add Local Spare Drive and press [ENTER]. A list of logical
drives displays.
Move the cursor bar to a logical drive, then press [ENTER]. The
unassigned disk drive will be associated with this logical drive as a Local
Spare.
Figure 4 - 37: Confirming Adding Local Spare Drive
When prompted to “Add Local Spare Drive?,” choose Yes to confirm.
4.9.2 Adding a Global Spare Drive
A Global Spare replaces the failed drive in any logical drive of a RAID
subsystem.
Figure 4 - 38: Add Global Spare Drive Page
Move the cursor bar to the drive that is not a member drive or a spare
(usually indicated as a "New Drive"), and then press [ENTER]. Choose
Add Global Spare Drive. When prompted to “Add Global Spare Drive?,”
choose Yes.