Terminal Operation
4-35
4.12.3.2 Flash All Drives
The Read/Write LEDs of all connected drives will light for a
configurable period of time. If the LED of the defective drive did
not light on the “Flash Selected Drive” function, use “Flash All
Drives” to verify the fault. If the “Flash All Drives” function is
executed, and the defective drive’s LED still does not respond, it can
be a drive tray problem or the drive is dead.
Figure 4 – 58: Flash All Drives
4.12.3.3 Flash All but Selected Drives
Except the selected drive, the Read/Write LEDs of all connected
drives will light for a configurable period of time ranging from 1 to
999 seconds. If an administrator cannot be sure of the exact location
of a specific drive, this function will help to indicate where it is.
This can prevent removal of the wrong drive when a drive fails and
is about to be replaced.