SCSI to SATA RAID Subsystem | Administrator’s Manual Data Integrity | en 155
Bosch Security Systems F.01U.027.802 | V1 | 2006.11
Fig. 10.7 Adding or Deleting Task Scheduler
Press [ENTER] on an existing schedule to display the configuration options. You may choose
to check information of a task schedule, to create a new schedule, or to remove a configured
schedule.
10.2.2 Task Scheduler Options
To configure a task schedule, you have the option to do any of the following:
Set the following values/intervals:
Execute on Controller Initialization
Fig. 10.8 Set for Task Scheduler Function
This option determines whether Media Scan is automatically conducted whenever the RAID
system is reset or powered on.
Start Time and Date
Fig. 10.9 Set for Date on Task Scheduler Function
Enter time and date in its numeric representatives in the following order: month, day, hour,
minute, and the year.
Execution Period
Fig. 10.10 Set for Time on Task Scheduler Function
The scheduler memorizes the date and the time the actions are to be executed. Select one of
the following:
If the action is intended to be executed for one time only, select “Execution Once.”