Installation 30
You can also directly associate the uplinks from two enclosures from different domains so that servers in the
two domains attached to the networks configured for those uplinks can communicate with one another. This
configuration establishes a private communication path between the two enclosures. However, the
communication path is public for all of those servers and applications associated with it. Traffic would not
flow from an upstream switch over that direct connection.
The two enclosures can communicate with each other by a dedicated uplink port or a shared uplink port
defined on each enclosure. These uplinks on the two enclosures can be “teamed” using LACP because both
domains run LACP active. The link between the two enclosures cannot have any additional active links
connected to other targets. Only networks defined for that link can be shared between the two enclosures.
Installing a VC-Enet module
The VC-Enet module can be used in an HP BladeSystem c7000 Enclosure or an HP BladeSystem c3000
Enclosure. The following illustrations show the VC-Enet module being installed in a c7000 enclosure.
To install the component:
1. Remove the interconnect blank.
NOTE: HP Virtual Connect works optimally in enclosures configured with HP Virtual Connect
interconnect modules only.