Compex Advanced SerialRAID Adapters SA33-3285-02 Przewodnik Instalacji Strona 1

Przeglądaj online lub pobierz Przewodnik Instalacji dla Networking Compex Advanced SerialRAID Adapters SA33-3285-02. Compex Advanced SerialRAID Adapters SA33-3285-02 Installation guide [en] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Installation Guide

7 1 33 Model T40 Serial Disk SystemInstallation GuideGA33-3280-03

Strona 2

viii 7133 Model T40 Installation Guide

Strona 3

Safety NoticesFor a translation of the danger and caution notices contained in this book, see the 7133Models D40 and T40 Serial Disk Systems and SSA A

Strona 4

Laser Safety InformationNotes:1. The information given here applies only to 7133s that have the Advanced SSAOptical Extender (Pair) feature.2. The Adv

Strona 5 - Contents

About This BookThis book provides installation instructions for any person who is required to install a7133 Model T40 Serial Disk System, which is a S

Strona 6

xii 7133 Model T40 Installation Guide

Strona 7 - Communications Statements

Installing and Testing the 7133 Model T40Are You Using the Correct Book? Do not use this book if you are installing a 7133Model 500 or Model 600 SSA D

Strona 8

Before You Install the 7133 Model T40This section describes the jobs that should be done and safety items that should beconsidered before you start to

Strona 9 - Communications Statements vii

Checking Mainline Electrical Power OutletsIf you are qualified technically, and have the necessary equipment, you should do thefollowing safety check

Strona 10

8. Verify that the grounding impedance is correct by using an ECOS 1020, 1023,B7106, C7106, or other appropriately-approved ground impedance tester.No

Strona 11 - Safety Notices

2. CAUTION:The 7133 Model T40 can weigh from 61.2 kg (135 lb) up to 76.2 kg (168 lb). Donot attempt to lift it.Move the 7133 into its operational posi

Strona 13 - About This Book

Checking the Items1. A detailed list of items is shipped with the 7133 Model T40. Ensure that you have allthe items that are shown on the list. Refer

Strona 14

2. If the 7133 has the Advanced SSA Optical Extender (Pair) feature, an AdvancedSSA Optical Extender (Pair) 14 is provided. For multi-mode configura

Strona 15

Connecting the 7133 Model T40 to the Using System1. Refer to Figure 42. At the back of the 7133, insert the key into the lock 2, and turn the keycou

Strona 16 - Installation Safety Notice

4. The disk drive modules of the 7133 are connected to an SSA attachment, or toother devices, by way of SSA loops. Before you go any further in these

Strona 17

b. The SSA connectors are related to the disk drive modules as follows:Connectors Disk Drive Modules1 and 4 Front disk drive modules 1 through 45 and

Strona 18 - Locating the 7133 Model T40

5. The SSA connectors at the back of the 7133 are mounted on four bypass cards(also known as SNBC cards). These bypass cards can operate in Automatic

Strona 19

Connecting SSA Cables to the 7133 Model T401. Attach identification labels to the SSA cables (see the Site and Hardware PlanningInformation manual, or

Strona 20 - Checking the Items

When you have completed the connections to the using system, go to “CheckingWhether a Remote-Power-On-Control Unit is Present” on page 19.Installing a

Strona 21

Installing and Connecting Advanced SSA Optical Extenders to the 7133 ModelT40Notes:1. It is the customer’s responsibility to obtain the fibre optic ca

Strona 22

1. When the fibre optic cables were installed, they were marked with some type ofidentification to enable you to recognize opposite ends of the same c

Strona 23

7 1 33 Model T40 Serial Disk SystemInstallation GuideGA33-3280-03

Strona 24

4. If you are connecting the fibre optic cables for single-mode operations, go to“Connecting Fibre Optic Cables for Single-Mode Operations”.If you are

Strona 25

3. Ensure that all fibre optic cables and SSA cables, if present, are correctlyconnected.4. Attention: Excessive movement at connections in a fibre op

Strona 26

5. Repeat steps 3 and 4 for all the optical extenders that are installed on the 7133.6. Find the uniters 4 that are supplied with the multi-mode con

Strona 27

Checking Whether a Remote-Power-On-Control Unit is Present1. Refer to Figure 10.2. Check whether a remote-power-on-control unit 1 is present in the

Strona 28

Connecting the Remote-Power-On Control Unit1. Using the preinstallation planning information, or other relevant information,determine whether the 7133

Strona 29

Connecting the 7133 Model T40 to the Power Source1. Refer to Figure 12.2. Ensure that the two short cables 3 are plugged into the power supplyassemb

Strona 30 - Class 1 Laser Product

6. Refer to Figure 13.7. Ensure that the power switch 1 of the remote-power-on control unit is setto | (on).8. If the power to the using system is s

Strona 31 - Equipment

9. Refer to Figure 14.10. Plug the power cable into a mainline electrical power outlet. If the power outlet hasa switch, switch it on.11. Check whethe

Strona 32

14. If the 7133 Power light comes on, go to step 15.If the light still does not come on, go to “MAP 2010: 7133 – START” in the 7133Models D40 and T40

Strona 33

v If the ID display is showing alternating IDs, go to step 18.18. If a failure occurs in the 7133, the ID display shows an error ID alternating with t

Strona 34

Fourth Edition (May 1999)This major revision supersedes GA33-3280-02. Technical changes are shown by a vertical line to the left of eachchange.The fol

Strona 35

If the error ID is HOT, the internal dc power switches on automatically afterthe temperature has decreased and has remained more than 5°C below thecri

Strona 36

Appendix A. Example ConfigurationsThe diagrams in this appendix show some example configurations for the 7133. All theconfigurations that are shown he

Strona 37

No improvement in performance is gained if the disk drive modules are moved to otherslots and connected in more than one loop.The cables are described

Strona 38

Larger ConfigurationsFour more disk drive modules can be added to the base configuration in one loop. Fora balanced subsystem, however, it is recommen

Strona 39

Largest Configurations with One 7133All 16 disk drive modules in a full 7133 can be connected in one loop. For a balancedsubsystem, however, it is rec

Strona 40

Multiple-Unit ConfigurationsAn SSA subsystem can include disk drive modules that are installed in more than one7133. You can connect up to 48 disk dri

Strona 41 - Simplest Configuration

The cables are described in “SSA Cables” on page 38. The internal connections ofModel T40 are shown in Note 4b on page 10.For information about the ru

Strona 42

Higher-Availability ConfigurationsFor higher availability, you can connect more than one SSA attachment in an SSA loop.2 2222222 222217133 unit 548112

Strona 43 - Larger Configurations

In loops that have multiple SSA attachments, you can often get best performance if youconnect the SSA attachments as equally as possible between the d

Strona 44 - 9 101112 13141516

22Using systemUsing systemB2B1A2A1A1A2B1B2Using systemUsing systemB2B1A2A1A1A2B1B2Using systemUsing systemB2B1A2A1A1A2B1B27133 unit 248112432156789101

Strona 45 - Multiple-Unit Configurations

ContentsCommunications Statements ...vFederal Communications Commission (FCC) Statement ...vJapanese Voluntary Control Council

Strona 46 - 43215678

Preventing the Isolation of Disk Drives in Higher-Availability ConfigurationsIf a loop contains four SSA attachments, with two attachments in each of

Strona 47 - 7133 unit 3

If, however, disk drive modules are connected into the link between two SSAattachments that are in the same using system, those disk drive modules bec

Strona 48

SSA CablesThis section gives details of the cables that are shown in the diagrams in this appendix.In Table 2, the item number is the number by which

Strona 49 - 7133 unit 1

Appendix B. Changing the Jumpers on a Bypass CardThis appendix describes how to change the mode of a bypass card.Attention: The bypass cards are elect

Strona 50

3. Unscrew the thumbscrews 1, 2, 3,or4 on the card that you are going toremove.4. Pull out the card.5. Refer to Figure 25.6. Lay the card down

Strona 51

a. Remove the jumpers, and install them into the required positions (see figures 25and 26).b. Reinstall the bypass cards, and tighten their thumbscrew

Strona 52 - SSA Cables

42 7133 Model T40 Installation Guide

Strona 53

Appendix C. Additional Information for RISC SystemsRelated PublicationsThis section lists the publications that are related to your using system.The I

Strona 54

Connecting to the Using System1. If the SSA adapter has not yet been installed into the using system, install it now(see the user or maintenance infor

Strona 55

Connecting SSA Cables to the SSA AdapterNote: For details of SSA cables, see “SSA Cables” on page 38.1. Attach identification labels to the SSA cables

Strona 56

Appendix B. Changing the Jumpers on a Bypass Card ...39Appendix C. Additional Information for RISC Systems ...43Related Publications ...

Strona 57 - Web Support Pages

4. Using the subsystem configuration information and the information from step 4 onpage 9 , plug an SSA cable into the appropriate connector on the SS

Strona 58

Installing and Connecting Advanced SSA Optical Extenders to the SSA AdapterNotes:1. It is the customer’s responsibility to obtain the fibre optic cabl

Strona 59 - 3 Connector A2

1. When the fibre optic cables were installed, they were marked with some type ofidentification to enable you to recognize opposite ends of the same c

Strona 60

Note: To prevent damage to the SSA connector screws, ensure that you use thespecial screwdriver (SSA tool, part 32H7059) to tighten them. Thescrewdriv

Strona 61

If you cannot fasten the bayonet connector, disconnect the cable, and tryagain.3. Ensure that all fibre optic cables are correctly connected to the ad

Strona 62

Connecting Fibre Optic Cables for Multi-Mode Operations1. Refer to Figure 30.2. Attention:v Ensure that each fibre optic cable is connected, via the m

Strona 63

8. Repeat step 7 for all the multi-mode conditioners that are installed on the SSAadapter.9. Ensure that all fibre optic cables are correctly connecte

Strona 64

Verifying the Installation1. If the 7133 is going to be used as an SSA RAID subsystem, go to the User’sGuide and Maintenance Information manual for yo

Strona 65

8. Refer to Figure 31.9. Ensure that the Power light 2 and the Receive light 1 of every optical extenderare on.If all the lights are on, go to ste

Strona 66

Appendix D. Additional Information for PC ServersRelated PublicationsThis section lists the publications that are related to your using system.v IBM P

Strona 67 - Verifying the Installation

Communications StatementsThe following statements apply to this product. The statements for other productsintended for use with this product appear in

Strona 68

Connecting to the Using SystemIf the SSA adapter has not yet been installed into the using system, install it now (seethe user or maintenance informat

Strona 69 - Web Support Page

6. If you are also connecting fibre optic cables, but have not done so yet, go to“Installing and Connecting Advanced SSA Optical Extenders to the SSA

Strona 70

Installing and Connecting Advanced SSA Optical Extenders to the SSA AdapterNotes:1. It is the customer’s responsibility to obtain the fibre optic cabl

Strona 71 - Present” on page 19

1. When the fibre optic cables were installed, they were marked with some type ofidentification to enable you to recognize opposite ends of the same c

Strona 72

Connecting Fibre Optic Cables for Single-Mode Operations1. Refer to Figure 34.2. Attention:v Ensure that each fibre optic cable is connected between t

Strona 73 - 3 SSA Loop A Port 2

5. If not already done, put the wrap cable and adapter assembly into its plastic bag,and put the bag into a safe place that is as close to the optical

Strona 74

Note: The fibre optic cables have:v An inner connector with an alignment lug that engages a slot in theconnector of the uniterv An outer, bayonet (pus

Strona 75

Verifying the Installation1. If the 7133 is going to be used as an SSA RAID subsystem, go to the user orservice information for your SSA adapter for i

Strona 76

If any light is off, go to “MAP 2330: 7133–Optical Extender” in the 7133 Models D40and T40 Serial Disk Systems: Service Guide if you are qualified tec

Strona 78

International Electrotechnical Commission (IEC) StatementThis product has been designed and built to comply with (IEC) Standard 950.Avis de conformité

Strona 79

Part Number: 34L6415Printed in the U.S.A.GA33-3280-0334L6415

Strona 80 - GA33-3280-03

Genehmigungsverfahren ist nach Paragraph 9 EMVG in Verbindung mit derentsprechenden Kostenverordnung (Amtsblatt 14/93) kostenpflichtig.Nach der EN 550

Komentarze do niniejszej Instrukcji

Brak uwag